CPS logo  

 
 
PRODUCTS
 
     
 

 

CLICK TO VIEW PREFERRED CATEGORY
 
   
   
 
 
>
THE ELIMINATOR™ LS3000. Electronic Refrigerant Leak Detector  
Fully automatic electronic refrigerant leak detector for all HFC, HCFC, CFC, SF6 gasses & blends. Exclusive POWERSHIFT software automatically monitors, controls & adjusts all critical instrument settings to ensure maximum leak search results under any job environment. Two separate visual LED displays enables user to pinpoint the exact location of leak source & the approximate size of that leak.
 
 
TECHNICAL SPECIFICATIONS
SENSOR TYPE
Cold Cathode Diode: Patented design allows fast, accurate detection of refrigerant leaks maintaining maximum sensitivity throughout the life of the sensor. Highly resistant to background contaminants including heavy condensation, oils, leak solutions, brake oils, radiator coolants, washer fluids, etc.
SENSITIVITY
Fully automatic selection allowing detection of a 0.25oz/yr (7g/yr) leak rate of HFC.
LEAK INDICATION
Audible Alarms: Two user-selectable audible alarm option (HIGH and LOW intensity)
TACHOMETER VISUAL DISPLAY
Tachometer-like bar graph display: Eight high intensity LEDs
GEARSHIFT VISUAL DISPLAY
Arranged in a gearshift pattern, 7 LEDs indicate the current sensitivity range of the unit and subsequent leak size
FLEX PROBE
14"/35.5cm long, 0.25"/6.4mm diameter
OPERATING TEMP
0 to 140°F / -18 to 60°C
POWER
75 hours battery life using three size "C" alkaline batteries. Auto OFF after 10 minutes of inactivity.
LOW BATTERY INDICATOR
Right most LED on Tachometer display illuminates to indicate low battery condition.
WEIGHT
1lb 2oz / 500g
WARRANTY
2 years excluding sensors and batteries
   
         
   
 
 
>
LEAK SEEKER ® LS790B. Electronic Refrigerant Leak Detector  
Combines the most advanced microcomputer circuitry with field proven Ion-pump sensor technology creating a highly sensitive, accurate electronic refrigerant leak detector. Over 100 computer generated tones and a high intensity bar graph display quickly alerts the user to varying halogen concentrations. Patented automatic calibration design eliminates the need for manual balance or tick rate adjustments while the user selectable 10 sensitivity ranges enables the LS790B to detect leaks of all refrigerants.
 
TECHNICAL SPECIFICATIONS
SENSOR TYPE
Patented Ion-Pump sensor with built-in selective filter housing
SENSITIVITY
0.25oz/yr (7g/yr) leak rate of HFC.
AUDIBLE ALARMS
Over 100 computer generated tones varying in intensity with leak size
VISUAL DISPLAY
10 high intensity bar graph display
LOCK-OUT MODE
Unique feature enables quick & easy locating of refrigerant leaks in highly contaminated search zones. In this mode, the unit will automatically & systematically store the recorded concentration levels of background refrigerant while initiating leak search, alarming only in the area of the highest recorded concentration level, the actual leak source.
FLEX PROBE
18"/45cm long metal cable probe
OPERATING TEMP
0 to 140°F / -18 to 60°C
POWER
40 hours battery life using 4 "AA" alkaline batteries. Auto OFF after 15 minutes of inactivity.
LOW BATTERY INDICATOR
5th LED constantly illuminates dimly indicating low battery condition.
WEIGHT
1lb 2oz / 500g
WARRANTY
2 years excluding sensors and batteries
   
         
   
 
 
>
LEAK SEEKER ® LS780B. Electronic Refrigerant Leak Detector  
Unique detection circuit design & patented Ion-Pump sensor technology combine to create an accurate field reliable refrigerant leak detector that is easy to use. A rugged, three position slide switch is used to turn the instrument ON & select either LO or HI sensitivity ranges. Visual indication of the leak size is provided by a high intensity LED varying in brightness with the concentration of the refrigerant detected.
 
TECHNICAL SPECIFICATIONS
SENSOR TYPE
Patented Ion-Pump sensor with built-in selective filter housing
SENSITIVITY
0.25oz/yr (7g/yr) leak rate of HFC
AUDIBLE ALARMS
Wide range audible alarm
VISUAL DISPLAY
High intensity LED display
FLEX PROBE
18"/36cm long metal cable probe
OPERATING TEMP
0 to 140F / -18 to 60C
POWER
40 hours battery life using 4 "AA" alkaline batteries. Auto OFF after 15 minutes of inactivity
LOW BATTERY INDICATOR
No illumination of LED indicates low battery
WEIGHT
1lb 2oz / 500g
WARRANTY
1 year excluding sensors and batteries
   
         
   
 
 
SPARE PARTS FOR LEAK DETECTORS  

LSXS3

LSXS3

LSXS

 
SPARE PARTS FOR LEAK DETECTORS
LSXB
(LS780A, LS780B, LS790A, LS790B) - Battery compartment cover
LSXBMK
(LS780B, LS790B) - Maintenance Kit: (1)LSXS + (1)LSXSF
LSXC
(LS780A, LS780B, LS790A, LS790B) - Leatherette carrying case
LSXC3
(LS3000) - Storage case LS3000
LSXE
(LS780A, LS780B, LS790A, LS790B) - Earphone
LSXMK
(LS780A, LS790A) - Maintenance kit • 2 pcs/St. LSXS + 2 pcs/St. LSXVF
LSXS3
(LS3000) - Sensor for LS3000
LSXS
(LS780A, LS780B, LS790A, LS790B) - Ion-pump sensor
LSXSF
(LS780B, LS790B) - Selective filter/housing
LSXSH
(LS780A, LS790A) - Aluminum Sensor housing
LSXVF
(LS780A, LS790A) - Water vapor filter LSXS3 LSXS
   
         
   
 
 
>
RM Refrigerant Monitor  
RMX11
RM
RMX12
Compact, highly reliable, yet economical refrigerant leak monitoring systems. Designed to monitor a single refrigerant in a single zone providing early warning of costly and environmentally damaging refrigerant leakage. Adjustable sensitivity settings between 100 to 1000PPM with an auxiliary 1⁄2 HP N.O. and N.C dry contact control function for operating an additional alarm or other safety device. Replacement sensors are interchangeable enabling the replacement of a failed sensor directly in the field without recalibration, minimizing "downtime."
TECHNICAL SPECIFICATIONS
SENSITIVITY
(LS780A, LS780B, LS790A, LS790B) - Battery compartment cover
ACCURACY
(LS780B, LS790B) - Maintenance Kit: (1)LSXS + (1)LSXSF
VISUAL ALARMS
(LS780A, LS780B, LS790A, LS790B) - Leatherette carrying case
AUDIBLE ALARMS
(LS3000) - Storage case LS3000
OPERATING TEMP.
(LS780A, LS780B, LS790A, LS790B) - Earphone
SENSOR MODULE
(LS780A, LS790A) - Maintenance kit • 2 pcs/St. LSXS + 2 pcs/St. LSXVF
CONTROL MODULE
(LS3000) - Sensor for LS3000
POWER
(LS780A, LS780B, LS790A, LS790B) - Ion-pump sensor
SENSOR FAILURE INDICATOR
(LS780B, LS790B) - Selective filter/housing
WEIGHT
(LS780A, LS790A) - Aluminum Sensor housing
WARRANTY
(LS780A, LS790A) - Water vapor filter LSXS3 LSXS
 
REPLACEMENT SENSORS
RMX11
Replacement Sensor for Refrigerant Monitor
RMX12
Replacement Sensor for Refrigerant Monitor
 
ITEM No.
REFRIGERANT TYPE
REPLACEMENT SENSOR
RM12
R-12
RMX12
RM134
R-134
RMX12
RMX11
R-22
RMX11
RM404
R-404A
RMX12
RM407
R-407
RMX11
RM410
R-410A
RMX12
RM502
R-502
RMX12
RM507
R-507
RMX12
   
         
   
 
 
>
GS20 GAS-SEEKER™ Combustible Gas Detector  
GS20
The GS20 is a completely self-contained gas detector designed to pinpoint combustible and toxic gas leaks of various types. An efficient and sensitive gas sensor is combined with solid-state circuitry, which provides an audible alarm that increases in pitch as the concentration of gas increases. The sensor has been extensively field-tested and is sensitive to a broad range of gases, in some cases providing a response at levels as low as 50 ppm.
 
DETECTABLE SENSITIVITY
500 - 10,000 ppm
Iso-Butane, Methane, Natural Gas, Propane, Carbon Monoxide, Hydrogen
500 - 10,000 ppm
Benzene, Methanol, Ethanol, Acetone, Nitro Methane, Methyl Ethyl Ketone
500 - 10,000 ppm
Ammonia
500 - 10,000 ppm
Sulfer Dioxide
AUDIBLE ALARMS
Wide range audible alarm
VISUAL DISPLAY
High intensity LED display
PROBE
6 ft. / 1.83 m long
OPERATING TEMPERATURE
0 to 140 °F / ~18 to 60 °C
POWER
25 hours battery life using 4 size "C" alkaline batteries
LO BATTERY INDICATOR
LED constantly illuminates dimly indicating low battery condition
WEIGHT
1 lb. 2 oz. / 500 g
WARRANTY
1 year excluding sensors and batteries
 
GSXS - Replacement Sensor Element for GS20
Caution: The GS20 is not intrinsically safe in Class I (Explosive) atmospheres.
   
   